Fibre Cement Cladding

Clear module layouts and interface coordination for the specified fibre-cement system.

01 / 04

Modules

Coordinate the panel modules with the project elevations.

02 / 04

Openings

Review opening edges and joint arrangements together.

03 / 04

Attachment

Coordinate attachment references for the selected system and project requirements.

04 / 04

Closeout

Bring layouts, interface details and review comments into the agreed closeout.

Read the sequence and scope
  1. Modules. Coordinate the panel modules with the project elevations.
  2. Openings. Review opening edges and joint arrangements together.
  3. Attachment. Coordinate attachment references for the selected system and project requirements.
  4. Closeout. Bring layouts, interface details and review comments into the agreed closeout.

Presentation only. Follow the specified project documents, selected system requirements and agreed review responsibilities. The reference geometry is illustrative and not to scale. Existing service limitations and technical notes remain below.

Further service context and original reference images
EXTERIOR CLADDING · FIBRE CEMENT

Equitone, Swisspearl and James Hardie panels installed as rainscreen — fire-rated, dimensionally stable, and field-proven in BC weather.

Fibre Cement Cladding
BRANDS
Equitone · Swisspearl · Hardie
ATTACHMENT
Concealed or face-fix
FIRE
Non-combustible
THICKNESS
8–12 mm

Scope

What we install

Through-coloured and factory-finished fibre cement panels in cassette, plank and large-format profiles.

  • Through-coloured + factory-finished panels
  • Concealed (riveted) or face-fixed mechanical attachment
  • Cassette, plank and large-format profiles
  • Full sub-framing + AVB + insulation scope
  • Trim, reveals, corners and closeouts shop-fabricated

Speccing fibre cement for your build?

Send the spec section + elevations — we’ll quote panel, sub-framing and closeouts.

Fibre-cement rainscreen — animated installation sequence

Project-specific reference details and governing notes
Fibre-cement rainscreen wall assembly, axonometric installation sequenceExploded axonometric diagram: sheathing on studs, vapour-permeable water-resistive air barrier, rough-opening flashing, thermal clips, mineral wool, vertical girts, vented cavity, base flashing with bug screen, fibre-cement panels, head J-trim and sloped flashings, water shedding outward including J-trim head weeps, detail callouts, and inside/outside corner return plan details. Not to scale, illustrative. FIBRE-CEMENT RAINSCREEN — INSTALLATION SEQUENCEFig Philp Group Inc. · Motion V1 benchmark · axonometric assembly — NTS, illustrative · profiles per FPG detail registerLAYER SEQUENCE01 SHEATHING ON STUDS02 W-R AIR BARRIER (VAPOUR-PERM)03 RO FLASHING + WINDOW10 TRIMS + FLASHINGS04 THERMAL CLIPSANCHORS ILLUSTRATIVE – NOTE 305 MINERAL WOOL (HATCHED)06 VERTICAL GIRTSFASTENED TO CLIP TABS – NOTE 307 VENTED CAVITY08 BASE FLASHING + BUG SCREEN09 FIBRE-CEMENT PANELFASTENING ILLUSTRATIVE – NOTE 3FIBRE-CEMENT PANEL – PER PROJECT SPEC – NTSJ-TRIM WEEPS (NOTE 1)WINDOW SCOPE:SEE NOTE 2WATER SHEDS OUTWARD – NEVER INWARD11 WATER SHED PATH12 DETAIL CALLOUTSHEADHEAD – J-TRIM + SLOPED FLASHINGJAMBJAMB TRIMSILLSILL – SLOPED + DRIP HEMBASEBASE – CLEARANCE + SCREENICINSIDE CORNER – PLAN BELOWOCOUTSIDE CORNER – PLAN BELOWHEAD (NTS)J-TRIM EXTENDS TO WALL PLANEPANELWEEPS(NOTE 1)WINDOW HEADSILL (NTS)WINDOW SILLSLOPE ~15 DEGHEM / DRIP KICKBASE (NTS)CLEARANCE – NO BEARINGSCREEN BEHIND PANEL PLANE – NEVER BENEATHNO WATER POCKET AT THE HEMMED DRIPOUTSIDE CORNER – PLAN (NTS)PANELCAVITYGIRTWOOLBARRIERSHEATHINGTRIMINSIDE CORNER (PLAN, NTS)BARRIERWOOLGIRTCAVITYPANELINSIDE CORNER TRIMLAYER STACK TURNS THE CORNER – CONTINUOUS – NTSJAMB (PLAN, NTS)WINDOW FRAMEJAMB J-TRIMPANEL EDGE IN RECEIVER – HEM INWARDNOTES – VERBATIM1. 24 in. o.c. maximum — project-specific example. Verify projectdrawings, approved shop drawings and manufacturer requirements.2. Scope responsibility varies by project — coordinate with theapproved responsibility matrix.3. Fasteners shown are illustrative only. Type, material, spacing,embedment, edge distance and structural capacity must follow theapproved project design and manufacturer requirements.