Metal cladding and flashing shop drawings
Clear panel arrangements and flashing references at openings, corners and terminations.
Request a metal-cladding drawing quote View a sample drawing set
- Panel starts & stops
- Opening & corner profiles
- Profile references
Canada-wide remote drafting; US enquiries welcome. Installation coverage is separate. Engineering design and professional sealing are separate services. Scope, timing and price are confirmed in the quotation.
Locate the sample openings and panel limits before assigning flashing references. Do not guess unconfirmed interfaces.
HF-1 is the authored sample head reference. Gauge, finish, support and connection details need project confirmation.
SF-1 is the sample sill reference. Frame location, sealant product and project drainage connections remain to be verified.
| Profile | Interface | Qty. |
|---|---|---|
| HF-1 | Head | 2 |
| SF-1 | Sill | 2 |
| JT-1 | Jamb | 4 |
References follow the two sample openings.
The two sample openings use two head, two sill and four jamb pieces. These are sample counts, not an order.
Read all four steps
- Find where each profile belongs. Locate the sample openings and panel limits before assigning flashing references. Do not guess unconfirmed interfaces.
- Focus on the head interface. HF-1 is the authored sample head reference. Gauge, finish, support and connection details need project confirmation.
- Coordinate the sill and frame. SF-1 is the sample sill reference. Frame location, sealant product and project drainage connections remain to be verified.
- Tie the profile to its location. The two sample openings use two head, two sill and four jamb pieces. These are sample counts, not an order.
Authored S0 sample · not for fabrication. Project sources and required technical reviews govern.
A detail for the actual interface
A detail for the actual interface
A typical profile does not answer every project question. At a window head, the drawing needs to identify the adjoining frame and panel faces, the return depth, the flashing arrangement and the references governing the detail. At a corner, it needs to explain how the two elevations meet rather than leave that decision to the crew.
Our drafting scope starts with the architect’s current documents and the specified metal system. Corrugated and other profiled wall cladding, standing-seam wall panels and formed flashings each need their own project information. We confirm which systems and interfaces are included before starting.
Choose the drawing scope you need
- Metal-cladding layouts
- Elevations showing panel direction, starts and stops, joint locations, opening alignment and transitions. Material identifiers and detail references are coordinated with the schedule.
- Flashing and trim details
- Head, jamb, sill, base, corner, parapet-interface and material-transition profiles, with the dimensions and notes established by the project requirements.
- Profile and location schedules
- Profile IDs tied to drawing locations, with material, finish and length information included where verified. Girths, quantities and individual fabrication tickets are included only when the quotation expressly covers them.
Example: identify a head flashing without guessing its size
Example: identify a head flashing without guessing its size
A coordinated detail identifies the profile, the opening it serves, the frame position, the adjacent panel edge and the applicable references. Unknown return depths or final lengths are marked for verification. A profile sketch is not released for cutting simply because it looks complete.
The illustrative drawing sample shows how an elevation, schedule and opening detail can be read together. It is not a detail to copy onto a project without checking its requirements.
Send the information that controls the detail
Send the information that controls the detail
Include the current architectural elevations and wall sections, the relevant specification, the metal-panel product information, accepted window or door shop drawings, available field measurements and any review comments. Tell us whether you need a full cladding package or only selected flashings and interfaces. The submission checklist helps organise the starting information.
Coordination drawings are not engineering or machine files
Engineering design, structural calculations, fastener capacities and professional sealing are separate services. FPG’s drawings coordinate with the project requirements and the responsible professionals; they do not replace their design. Machine-ready files, forming allowances, cutting lists and fabrication release require a separately defined scope and the fabricator’s requirements.
For specialist panel systems, see our fibre-cement panel shop drawings and ACM and MCM panel shop drawings.
Frequently asked questions
Can you draw only the flashings?
Yes. Identify the elevations, openings and profile types required. We will confirm the available references, the specific deliverables and the revision allowance in the quotation.
Can we send a marked-up sketch?
Yes. Send it with the project references and verified dimensions available. We will identify information still needed; a sketch does not establish an unverified measurement or design approval.
Do you provide installation outside British Columbia?
This page offers remote drafting. Installation is a separate service with separate geographic coverage. US project scope, units, formats and professional responsibilities are confirmed before acceptance.
Tell us which metal-cladding details you need
Include the project location, cladding system, drawing requirements and requested deadline. Scope, availability and price are confirmed in the quotation.
Request a shop-drawing quote
Tell us about the project. You don't need to send drawings yet. If your document set is ready, use the secure upload form instead.
Enquiry received
FPG will review the scope and reply by email. This confirms that your enquiry was received. It is not a price, a delivery date or acceptance of drawings.
Ready to send documents? Use the secure upload form.